Maintained vs Non-Maintained Emergency Lighting
Maintained emergency luminaires are lit at all times; non-maintained fittings only illuminate when the normal supply fails. Each suits different areas and uses.
Emergency luminaires operate in one of two modes: maintained or non-maintained. The difference is simply whether the fitting is lit during normal operation or only on failure of the supply.
Maintained
A maintained luminaire is illuminated all the time — from the normal supply during regular use, and from its battery when the supply fails. Exit signs in places of assembly (such as cinemas, theatres and clubs) are commonly maintained so they are always visible.
Non-maintained
A non-maintained luminaire is off during normal conditions and only illuminates when the normal supply fails. It is common in workplaces such as offices, where general lighting is already on when the building is occupied.
Choosing between them
The choice depends on the type of premises and how it is used. Places where people gather in darkness or reduced lighting typically use maintained exit signage. Workplaces normally lit during occupancy often use non-maintained escape lighting. A fire risk assessment and BS 5266 guide the decision. Both modes require the same monthly and annual duration testing.
Related service
Emergency Lighting Installation
Installation of emergency lighting to support BS 5266 good practice.
Learn moreMore in this topic
Knowledge article
Emergency Lighting Annual Duration Testing
The annual emergency lighting test discharges the batteries for their full rated duration (commonly 3 hours) to confirm the system lasts the required period.
Learn moreStandard explained
BS 5266 Overview: Emergency Lighting Standard
BS 5266 is the UK code of practice for emergency lighting — covering design, installation and maintenance so illumination is provided when the normal supply fails.
Learn moreKnowledge article
Common Emergency Lighting Defects
Common emergency lighting defects include failed batteries, faulty luminaires, missing coverage, no logbook and fittings that light up but fail the duration test.
Learn moreKnowledge article
Emergency Lighting Explained
Emergency lighting provides illumination automatically when the normal supply fails, helping people evacuate safely — governed by BS 5266.
Learn moreThis article provides general guidance and distinguishes legislation, British Standards and good practice. It is not legal advice. Always confirm the specific duties applying to your property and tenure.